{"product_id":"usw-mission-critical-ubiquiti-unifi-ups-poe-switch-usw-mission-critical-9-port-switch-with-ups-backup-built-in","title":"USW-Mission-Critical - Ubiquiti UniFi UPS PoE Switch USW-Mission-Critical 9 Port Switch with UPS Backup built in","description":"\u003cdiv class=\"kw-advanced-description\" style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#333;line-height:1.7;max-width:860px;margin:0 auto;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;color:#111;margin:24px 0 12px 0;border-bottom:2px solid #eaeaea;padding-bottom:8px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cdiv data-block=\"features\" data-scroll-amount=\"100\" data-scroll-top=\"true\" data-trigger-css=\"d-xl-none\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eUbiquiti Unifi USW-Mission-Critical 9-Port Gigabit L2 Managed PoE Switch (120W) with 368Wh Battery \u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eA switch with an integrated 368Wh lithium-ion battery capable of providing uninterruptible PoE to 8 devices.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0759\/5088\/2861\/files\/20250724185058_718_7ed9ffa7-acd4-488d-8b4f-966e5f1721dc.png?v=1785393395\" style=\"max-width: 100%; height: auto; display: block; margin: 16px auto; border-radius: 6px;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0759\/5088\/2861\/files\/20250724185108_388_080bcf28-7bfd-46f0-8ba6-8a89785dedd0.png?v=1785393402\" style=\"max-width: 100%; height: auto; display: block; margin: 16px auto; border-radius: 6px;\"\u003e\u003c\/p\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eDeployment\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0759\/5088\/2861\/files\/20250724185152_389_a34637c8-ab12-466b-8d30-6145ffa10f40.png?v=1785393411\" style=\"max-width: 100%; height: auto; display: block; margin: 16px auto; border-radius: 6px;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;color:#111;margin:24px 0 12px 0;border-bottom:2px solid #eaeaea;padding-bottom:8px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv data-block=\"specifications\" data-scroll-amount=\"100\" data-scroll-top=\"true\" data-trigger-css=\"d-xl-none\"\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;margin-top:8px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e442 x 480 x 44 mm (17.4 x 18.9 x 1.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePort Layout\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e1 GbE RJ459 (4 PoE+; 4 PoE++) (1G\/100M\/10M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMax. PoE Output\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUp to PoE++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eTotal PoE Availability\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e120W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRedundancy\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eBattery Power Backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eLayer 3\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eForm Factor\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eRack mount (1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSwitching Capacity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e18 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eTotal Non-Blocking Throughput\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e9 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eForwarding Rate\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e13 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSupported VLANs\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMAC Address Table Size\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e8,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePacket Buffer Size\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e0.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eAccess Lists\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eIPv4 128MAC 128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eLACP Port Aggregation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSTP \u0026amp; RSTP\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eAdvanced IGMP Configuration (Querier, Fast Leave, Router Port)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eIGMP Snooping\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003e802.1X Control\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMAC-Based ACLs \u0026amp; Device Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eDHCP Snooping \u0026amp; Guarding\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eEgress Rate Limit\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eFlow Control\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eStorm Control\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMulticast \u0026amp; Broadcast Rate Limiting\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMAC Address Blocking\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eIP-Based ACLs \u0026amp; Network Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMAC-Based Port Restriction\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePort Isolation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePort Mirroring\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eJumbo Frames\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eLLDP-MED\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eVoice VLAN\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eLoop Protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePoE Ports\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003ePoE+4PoE++4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMax. PoE Wattage per Port by PSE\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003ePoE+32WPoE++64W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMax. Power Consumption\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e50W (Excluding PoE Output)240W (Including PoE Output and AC Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePower Method\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUniversal input, 100-240V AC, 50\/60 HzExternal battery input, 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePower Input Method\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eAC inputDC input (Backup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eAC\/DC, internal, 240W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSupported Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e100-240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eManagement\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eEthernetAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eHeat Dissipation (Excluding PoE Output)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e170.6 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eWithout mount: 9 kg (19.9 lb)With mount: 9.2 kg (20.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eEnclosure Material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eSGCC steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eMount Material\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eSGCC steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSupported Rack Depth\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e482.6 mm (19\") four-post racksPosts depths ranging from 700 to 1,000 mm (27.6-39.4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eLCM Display\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e1.3\" touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eESD Protection\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eAir\/contact: ± 24kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eAmbient Operating Temperature\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e-5 to 40° C (23 to 104° F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eAmbient Operating Humidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e5 to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eNDAA Compliant\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eCE, FCC, IC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eApplication Requirements\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUniFi NetworkVersion 6.2.26 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":67018935795757,"sku":"USW-Mission-Critical","price":2380.99,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/5088\/2861\/files\/SWHUBI6323236.jpg?v=1783827123","url":"https:\/\/kwtech.co.nz\/de\/products\/usw-mission-critical-ubiquiti-unifi-ups-poe-switch-usw-mission-critical-9-port-switch-with-ups-backup-built-in","provider":"KW Tech","version":"1.0","type":"link"}