{"product_id":"vertiv-vrt_gxt5-2000irt2uxl_liebert-gxt5-on-l","title":"VERTIV VRT_[GXT5-2000IRT2UXL]_LIEBERT GXT5 ON-L","description":"\u003cdiv class=\"kw-advanced-KW Tech\" style=\"font-family:'Helvetica Neue',Arial,sans-serif;color:#333;line-height:1.7;max-width:860px;margin:0 auto;\"\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;color:#111;margin:24px 0 12px 0;border-bottom:2px solid #eaeaea;padding-bottom:8px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cdiv data-block=\"features\" data-scroll-amount=\"100\" data-scroll-top=\"true\" data-trigger-css=\"d-xl-none\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eVertivTM Liebert® GXT5 UPS - 2 kVA\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eIntelligent, Versatile, and Reliable Power Protection for Your Critical Applications\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eThe Vertiv™ Liebert® GXT5 UPS is an online double conversion UPS solution which offers premium power outage protection and continuous power conditioning in a compact and flexible rack\/tower form factor.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eThe Vertiv Liebert GXT5 single phase UPS operates with high power efficiency, making it ideally suited to protect critical infrastructure in both centralized and edge network applications.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eScalable runtime options with matching external battery cabinets offer additional flexibility when extended uninterrupted power is required. Plus, the Liebert® GXT5 provides battery health status and replacement date prediction for intelligent battery health management.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eThe UPS system is easy to deploy and maintain due to its user-friendly LCD interface and remote management capabilities supported by the Vertiv™ RDU101 communications card which makes the Liebert GXT5 compatible with infrastructure management solutions such as Vertiv™ LIFE Services, environmental sensors, Vertiv™ Power Insight, and more.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003eWith market leading efficiency and unity power factor operation, the Liebert GXT5 will meet your critical application needs. You can rest assured that your business is protected with this Vertiv solution.\u003c\/p\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eVertiv Liebert GXT5 Features\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eLeading UPS Technology\u003cbr\u003e\u003c\/strong\u003e- High output PF = 1.0\u003cbr\u003e- Full color graphic LCD display with gravity sensing\u003cbr\u003e- Individually programmable outlets for power-cycling hung equipment and to optimize battery runtime for critical applications\u003cbr\u003e- External battery cabinets with auto-detection\u003cbr\u003e- Battery health status and replacement date prediction\u003cbr\u003e- Remote management, update and configuration\u003cbr\u003e- Optimized thermal management and variable speed fan\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eEfficient and Green Product\u003cbr\u003e\u003c\/strong\u003e- High efficiency (up to 94%) in online mode\u003cbr\u003e- Even higher efficiency (up to 98%) in ECO mode\u003cbr\u003e- Programmable outlets for scheduled shutdown of equipment that is not in use, resulting in significant power savings\u003cbr\u003e- RoHS and REACH compliance\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eSolutions Wide\u003cbr\u003e\u003c\/strong\u003e- Compact Rack \/ Tower design\u003cbr\u003e- Broad range of services and extended warranties\u003cbr\u003e- Easy to install, configure and operate\u003cbr\u003e- Vertiv™ Power Insight management software\u003cbr\u003e- Optional Vertiv RDU101 network card with advanced features for UPS management\u003cbr\u003e- Compatibility with environmental sensors\u003cbr\u003e- Integrated dry-contacts with selectable definition\u003cbr\u003e- Serial port for out-of-band management with Avocent Serial Consoles\u003cbr\u003e- Automatic internal bypass and optional external maintenance bypass\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eVertiv™ Liebert® GXT5 Highlights\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eHow You Benefit from the Liebert® GXT5 UPS\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eDesigned for high availability\u003cbr\u003e\u003c\/strong\u003e- With \u003cstrong\u003eindividually controlled output sockets\u003c\/strong\u003e, you can manage power to individual devices without impacting other critical network equipment operation\u003cbr\u003e- Minimum downtime of the device provided by \u003cstrong\u003ehot-swappable, user-replaceable battery \u003c\/strong\u003emodules which can be changed during operation\u003cbr\u003e- \u003cstrong\u003eAutomatic self-test\u003c\/strong\u003e\u003cbr\u003e- \u003cstrong\u003eExtended runtimes \u003c\/strong\u003eprovided by the addition of external battery cabinets\u003cbr\u003e- \u003cstrong\u003eImproved battery care \u003c\/strong\u003eby temperature compensated battery charging\u003cbr\u003e- \u003cstrong\u003eIntelligent battery health management \u003c\/strong\u003eensures a longer service life (optimized battery maintenance and replacement when needed)\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eUser-friendly installation and operation\u003cbr\u003e\u003c\/strong\u003e- Easy to read, gravity sensing \u003cstrong\u003egraphical color display\u003c\/strong\u003e\u003cbr\u003e- \u003cstrong\u003eIntuitive user interface\u003c\/strong\u003e, local configuration and management\u003cbr\u003e- Support for the new Vertiv suite of \u003cstrong\u003eremote management tools \u003c\/strong\u003e(Vertiv™ Power Insight, RDU101 network interface card and serial connectivity support)\u003cbr\u003e- \u003cstrong\u003eAutodetection of external battery cabinets \u003c\/strong\u003eenables faster deployment and accurate runtime information\u003cbr\u003e- \u003cstrong\u003eRemote UPS firmware upgrade \u003c\/strong\u003ecapability ensures your UPS has the latest features and enhancements\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eOptimized energy and capacity management\u003cbr\u003e\u003c\/strong\u003e- ECO operating mode with \u003cstrong\u003eup to 98% efficiency\u003c\/strong\u003e\u003cbr\u003e- \u003cstrong\u003eEfficiency \u003c\/strong\u003ein online double conversion mode up to 94%\u003cbr\u003e- The \u003cstrong\u003ehigher power factor (1.0) \u003c\/strong\u003eensures the connection of more loads and IT equipment\u003cbr\u003e- 4 \u003cstrong\u003eindividually programmable output sockets \u003c\/strong\u003ecan be used to extend runtime for the most critical loads and smart disconnection of the less critical ones\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eSeamless connectivity\u003cbr\u003e\u003c\/strong\u003e- Four onboard, user-definable dry contact I\/O for \u003cstrong\u003eintegration of support management systems\u003c\/strong\u003e\u003cbr\u003e- Supports \u003cstrong\u003eSNMP, web, and environmental sensors \u003c\/strong\u003ewith the optional RDU101 communications card\u003cbr\u003e- \u003cstrong\u003eSerial connection \u003c\/strong\u003efor integration of Avocent® ACS product or direct serial management and control of the UPS\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e \u003c\/p\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eWhat's in the box\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e- Liebert GXT5 UPS\u003cbr\u003e- Quick Installation Guide and Safety Instructions\u003cbr\u003e- USB type A to B cable (2m)\u003cbr\u003e- RS232 cable (1.8 m)\u003cbr\u003e- Adjustable 4-post rack mounting kit with screws, ears and hardware\u003cbr\u003e- Stabilizing feet for tower configuration\u003cbr\u003e- 2 x IEC C13 to C14 output cables (2m) for 750 - 1000 - 1500 VA; 3 cables for 2000 - 3000 VA\u003cbr\u003e- Input power cables (UK, AUS, Schuko) for 2000 - 3000 VA (2.5 m)\u003cbr\u003e- Free Vertiv Power Assist software for local UPS status and shutdown, or Vertiv Power Insight for remote-network management\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;font-size:15px;line-height:1.6;color:#444;\"\u003e\u003cstrong\u003eDownload data sheet\u003c\/strong\u003e: \u003ca href=\"https:\/\/www.vertiv.com\/49527a\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/liebert-gxt5-750va-to-3kva-brochure.pdf\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.vertiv.com\/49527a\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/liebert-gxt5-750va-to-3kva-brochure.pdf\u003c\/a\u003e\u003c\/p\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:700;color:#111;margin:24px 0 12px 0;border-bottom:2px solid #eaeaea;padding-bottom:8px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv data-block=\"specifications\" data-scroll-amount=\"100\" data-scroll-top=\"true\" data-trigger-css=\"d-xl-none\"\u003e\n\u003cdiv\u003e\n\u003ch3 style=\"font-size:18px;font-weight:600;color:#222;margin:20px 0 10px 0;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;margin-top:8px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eModel Number\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eGXT5-2000IRT2UXL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRatings (VA\/W)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e2000 VA \/ 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eDimensions (mm) Unit, D×W×H\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e470×430×85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eUnit Weight (kg)\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRated Volatge\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRated Frequency\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eFrequency Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e40 to 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003ePower Factor\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e≥0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eInput Power Cord\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eC20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e200\/208\/220\/230\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eWaveform\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eInverter Overload Capability\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e\u0026gt;200% minimum 250 ms, 150 to 200% for 2 seconds; 125 to 150% for 50 seconds; 105 to 125% for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eEfficiency in Online Mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUp to 93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eActive Eco Mode\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUp to 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eOutput Receptacles\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e(8) EN60320\/C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRated Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eCharger Current\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eNominal 2.2 A; Maximum 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eValve-regulated, non-spillable, lead acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eQty x V x Rating\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e4 x 12 V x 9.0 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eEnd Cell Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e1.67 V\/cell (discharge voltage per cell will be from 1.67 Vdc to 1.90 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eFloating Voltage\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eEqualize charge: 2.35 V\/cell; Float charge: 2.27 V\/cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eBattery Voltage Range\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e40 Vdc to 56.4 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eOperating Temperature, °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eFull power up to 40 ºC (up to 50 ºC with derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eStorage Temperature, °C\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e-20 to 60 (contain batteries will be from -15 to 40 °C.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e0 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eOperating Elevation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eUp to 3,000 m at 25°C without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eAudible Noise\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003e\u0026lt;46 dBA max @ 3ft. (1 m) front and sides \u0026lt;45 dBA max @ 3 ft. (1 m) rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSafety\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eCE, UL-1778 (Fifth Edition), C-UL listed, IEC 62040-1: 2008 (First Edition) + Am 1:2013, EN 62040-1:2008+A1:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eRFI\/EMI\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eCISPR22 Class A (RFI)\/ FCC Part 15 (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eTransportation\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eISTA Procedure 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:9px 14px;background:#f8f8f8;width:35%;font-weight:600;text-align:left;\"\u003eSurge Immunity\u003c\/th\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:9px 14px;\"\u003eANSI C62.41 Category B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"VERTIV","offers":[{"title":"Default Title","offer_id":67044178919469,"sku":"1202010","price":4217.6,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/5088\/2861\/files\/UPSVTV5039877.jpg?v=1784250555","url":"https:\/\/kwtech.co.nz\/products\/vertiv-vrt_gxt5-2000irt2uxl_liebert-gxt5-on-l","provider":"KW Tech","version":"1.0","type":"link"}